Romet Electronics

ADVANCED ELECTRONIC MODEL S (AdEM-S)

 

AdEM-S Romet Electronic Meters

AdEM®-S is an electronic replacement for mechanical STD CTR to also include audit trail and communications. AdEM®-S meters are intended for use where compensation to standard base conditions is not required. The AdEM®-S has a built-in audit trail which will store certain metrological information over a predetermined time period.

* Interval 100 days hourly reads (6 items)

* Daily Logger 672 days

* Alarm Logger 102 events

* Event Logger 200 events

The AdEM®-S also has the capability to generate other parameters, such as: flow rate, peak flow, previous day volume, daily volume, various alarms, battery level and voltage readings. Scroll button or optional remote keyboard or RometLink computer software ensure reliable, quick access to this information.

Since the AdEM®-S being of electronic type doesn’t have any mechanical parts that could cause drag, the rangeability of the meter is increased. Low flow volumetric linearization feature enhances the rangeability even further up to 200:1 or better, with an error of less than ± 1.0%.

This new compact design module offers up to 20 years battery life in a service-free, weather resistant enclosure.

This device has fully developed one way communication features using RometLink computer software.

The maximum allowable operating pressure (MAOP) of the pressure body is:

175 psig / 12 bar / 1206 kPa.

AVAILABLE IN ANSI AND DIN FLANGES

Untitled-1

 

 


ADVANCED ELECTRONIC CORRECTOR (AdEC)

adec-mounted

When temperature, pressure or supercompressibility factors are a matter for concern, the AdEC® is able to calculate and process the required factors for volume compensation. The AdEC® has a built in daily log, audit trial, and event logger (data logging system) which will store certain metrological information over a predetermined time period.

* Interval 105 days hourly reads (23 items) or 409 days hourly reads (4 items)

* Daily Logger 1024 days

* Alarm Logger 101 events

* Event Logger 200 events

The AdEC® also has the capability to generate other parameters, such as: uncorrected flow rate, corrected flow rate, uncorrected peak flow, previous day uncorrected volume, previous day corrected volume, daily uncorrected volume, daily corrected volume, various alarms, battery level and voltage, pressure and temperature readings, live or fixed super-x factor, etc..

A scroll button mounted on the bottom of enclosure or RometLink computer software ensure reliable, quick access to this information.

AdEC® meters have a non-compensated and a compensated electronic index and an additional non-compensated mechanical index counter (Meter mount version only).

Available in mounted or remote versions.

The meter mount version is mounted on a STD ID, DCID, or TCID meter.

The remote mount version is remotely connected by cable to a suitable STD CTR with pulser.

This device has fully developed one way communication features using RometLink computer software or Implemented Modbus RTU protocol that makes this device available for other communication and control systems, e.g.: SCADA.

Untitled-1

 

 


ADVANCED ELECTRONICS MODULE T VERSION (AdEM-T)

 

adem-t-1000

AdEM®-T index to the required base condition. The AdEM®-T has a built-in audit trail which will store certain metrological information over a predetermined time period.

* Interval 100 days hourly reads (6 items)

* Daily Logger 672 days

* Alarm Logger 102 events

* Event Logger 200 events

The AdEM®-T also has the capability to generate other parameters, such as: flow rate, peak flow, previous day volumes, daily volumes, various alarms, battery level and voltage, temperature readings, fixed pressure factor, etc.. Scroll button or optional remote keyboard or RometLink computer software ensure reliable, quick access to this information.

Since the AdEM®-T being of electronic type doesn’t have any mechanical parts that could cause drag, the rangeability of the meter is increased. Low flow volumetric linearization feature enhances the rangeability even further up to 200:1 or better, with an error of less than ± 1.0%.

This new compact design module offers up to 20 years battery life in a service-free, weather resistant enclosure.

This device has fully developed one way communication features using RometLink computer software.

The maximum allowable operating pressure (MAOP) of the pressure body is:

175 psig / 12 bar / 1206 kPa.

AVAILABLE IN ANSI AND DIN FLANGES

Untitled-1

 

 


ADVANCED ELECTRONIC MODULE PTZ VERSION (AdEM-PTZ)


adem-ptz-gauge-16M-B3-1
AdEM®-PTZ is a technological advancement of AdEM®-T to also include pressure and supercompressibility compensation. When temperature, pressure or supercompressibility factors are a matter of concern, the AdEM®-PTZ is able to calculate and process the required factors for volume compensation. The AdEM®-PTZ has a built-in audit trail which will store certain metrological information over a predetermined time period.* Interval 64 days hourly reads (21 items) or 256 days hourly reads (4 items)* Daily Logger 1024 days* Alarm Logger 101 events* Event Logger 166 eventsThe AdEM®-PTZ also has the capability to generate other parameters, such as: flow rate, peak flow, previous day volumes, daily volumes, various alarms, battery level and voltage, temperature readings, live or fixed super-x factor, etc.. Scroll button or optional remote keyboard or RometLink computer software ensure reliable, quick access to this information. Since the AdEM®-PTZ being of electronic type doesn’t have any mechanical parts that could cause drag, the rangeability of the meter is increased. Low flow volumetric linearization feature enhances the rangeability even further up to 200:1 or better, with an error of less than ± 1.0%.This new compact design module offers 10 to 20 years battery life in a service-free, weather resistant enclosure.This device has fully developed one way communication features using RometLink computer software or Implemented Modbus RTU protocol that makes this device available for other communication and control systems, e.g.: SCADA.The maximum allowable operating pressure (MAOP) of the pressure body is:175 psig / 12 bar / 1206 kPa.

AVAILABLE IN ANSI AND DIN FLANGES

Untitled-1

 

 